Wednesday, July 23, 2025

Process Chain – Processed with Errors

While checking process chain there can following message displayed:



Processes with Error        Message No. RSPC022

Diagnosis

Error occurred when checking the process chain.

System Response

When errors occur, the system does not activate the chain.

Procedure

Call the relevant messages for the processes that are marked in yellow and red using the context menu.

 

The problem with that message is that it doesn’t say what process has the error. The error is just shown as generic and from the message it is not possible to say what is wrong.

To get to know what process the error is related to a debugging is needed. Check of PC’s processes are executed by method CHECK of ABAP class CL_RSPC_CHAIN. There is an internal table called E_T_CONFLICTS holding information about the erroneous process:


In my case the error was related to aDSO activation process. The aDSO object technical name is shown in field MSGV1.